Show simple item record

contributor authorMubashshir Ahmad
contributor authorSoheil Shafaei
contributor authorAmit H. Varma
contributor authorRon Klemencic
date accessioned2024-12-24T10:03:59Z
date available2024-12-24T10:03:59Z
date copyright9/1/2024 12:00:00 AM
date issued2024
identifier otherJSENDH.STENG-13453.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4298233
description abstractFour different composite coupling beam-to-composite plate shear wall (CPSW/CF) connection details were developed and proposed. Six large-scale specimens representing the four connections were designed, fabricated, and tested. The connections were subassemblies of coupled composite plate shear walls/concrete filled (CC-PSW/CF) subjected to cyclic lateral loading. The coupling beams were designed to be flexure-critical with clear span-to-depth (Lb/d) ratios of 3.5 or 5.1. This paper presents the experimental program, capacities, and detailed behavioral observations of all six specimens. The effects of connection type and Lb/d ratio on the ultimate strength, stiffness, ductility, and failure modes are evaluated. Major limit states and events included yielding of the steel plates comprising the coupling beam, followed by local inelastic buckling, fracture initiation in the base metal (near the weld toes), and fracture propagation through the beam flange and web plates, leading to loss of flexural strength and failure. All the connections were able to develop and transfer the flexural capacity of the composite beam section. The composite coupling beams developed flexural capacities (10%–50%) greater than those calculated using the plastic stress distribution method. The underlying reasons for this overstrength are evaluated. The AISC flexural stiffness equation for filled composite sections could reasonably estimate the stiffness of the composite coupling beam sections. A fiber-based model of the cross-section was used to calculate the section moment–curvature response of the filled composite beam sections. The calculated flexural capacities were consistent with those calculated by the plastic stress distribution method but lower than the experimentally observed values. The flexural stiffness values were slightly higher than the experimental results. For more accurate comparisons with experimental results, a numerical model is needed to estimate the cyclic lateral load-deformation response while accounting for the effects of local buckling, low cycle fatigue, and fracture.
publisherAmerican Society of Civil Engineers
titleExperimental Investigation of Composite Coupling Beam-to-Wall Connections in Coupled C-PSW/CF Systems
typeJournal Article
journal volume150
journal issue9
journal titleJournal of Structural Engineering
identifier doi10.1061/JSENDH.STENG-13453
journal fristpage04024114-1
journal lastpage04024114-20
page20
treeJournal of Structural Engineering:;2024:;Volume ( 150 ):;issue: 009
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record