Show simple item record

contributor authorAjla Aksamija
contributor authorSuncica Milosevic
date accessioned2024-04-27T20:58:57Z
date available2024-04-27T20:58:57Z
date issued2023/12/01
identifier other10.1061-JAEIED.AEENG-1589.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4296381
description abstractThis paper presents a study where thermal heat transfer simulations were used to evaluate the potential for condensation among 11 different window systems, ranked by their respective heat transfer coefficients (U-factors) and condensation resistance (CR) rating values. The objectives were to determine exterior environmental conditions under which condensation would occur, to measure the extents of condensation, to compare the extents of condensation among the analyzed window systems, and to evaluate relationships of condensation potential with the ascribed U-factor and CR values. Using THERM software (version 7.7), temperature distribution within the head, jamb, and sill window detail conditions were simulated and the lowest temperatures along the interior surfaces of analyzed window systems were recorded and analyzed for linear extents and location of condensation. Results demonstrate that the conditions under which condensation occurs and the extents of condensation on window surfaces are not driven by the U-factor or CR values, but rather by the individual performance of each window system component (frame, glass, and spacer) and their material properties. This paper evaluates the potential for condensation among 11 different window systems, ranked by their respective thermal performance indicators, the heat transfer coefficients (U-factors), and their condensation resistance indicators, also known as the condensation resistance (CR) rating values. The goal was to assess the relationships of condensation with both the U-factor and CR values, to provide a visual understanding of what the CR values mean for selection of fenestration systems, and to provide a framework for preventing condensation. The overall results demonstrate that condensation potential and condensation extents are not only driven by the U-factor and the CR value, as presumed in conventional practice, but by the individualized performance of a specific combination of window components (frame, glass, and spacer), as the lowest-performing component drives condensation.
publisherASCE
titleCondensation Study: Thermal Analysis of Aluminum-Framed Window Systems under Different Environmental Conditions
typeJournal Article
journal volume29
journal issue4
journal titleJournal of Architectural Engineering
identifier doi10.1061/JAEIED.AEENG-1589
journal fristpage04023034-1
journal lastpage04023034-14
page14
treeJournal of Architectural Engineering:;2023:;Volume ( 029 ):;issue: 004
contenttypeFulltext