Show simple item record

contributor authorAbdul-Hamid Zureick
contributor authorBlaine Weinmann
date accessioned2023-04-07T00:35:29Z
date available2023-04-07T00:35:29Z
date issued2022/10/01
identifier other%28ASCE%29CC.1943-5614.0001244.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4289345
description abstractAn in-depth assessment is conducted to examine the analytical and experimental results that formed the basis of the net-section tensile rupture strength of single-bolt connections, stipulated in the ASCE Pre-Standard for Load and Resistance Factor Design (LRFD) for Pultruded Fiber-Reinforced Polymer (FRP) Structures. As a result of our findings, we propose that current ASCE net-tension tensile strength design criteria be consolidated and revised to a simple form attractive for routine uses by practicing engineers. The proposed simplified nominal resistance equation and the results from single-bolt double-lap connection experiments were used to determine the resistance factor ϕ with a target reliability index of 4.5.
publisherASCE
titleRevisiting the Net-Section Tensile Rupture Strength Limit State of Single-Bolt Connections in Pultruded Structures
typeJournal Article
journal volume26
journal issue5
journal titleJournal of Composites for Construction
identifier doi10.1061/(ASCE)CC.1943-5614.0001244
journal fristpage04022050
journal lastpage04022050_9
page9
treeJournal of Composites for Construction:;2022:;Volume ( 026 ):;issue: 005
contenttypeFulltext