Show simple item record

contributor authorMarco Baiguera
contributor authorTiziana Rossetto
contributor authorIan N. Robertson
contributor authorCrescenzo Petrone
date accessioned2022-05-07T20:24:34Z
date available2022-05-07T20:24:34Z
date issued2021-11-26
identifier other(ASCE)ST.1943-541X.0003256.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4282390
description abstractThe new ASCE 7-16 Chapter 6 offers a comprehensive and practical methodology for the design of structures for tsunami loads and effects. While it provides prescriptive tsunami loading and design requirements, Chapter 6 also allows for the use of performance-based nonlinear analysis tools. However, the specifics of load application protocol and system and component evaluation for such a nonlinear approach are not provided. This paper presents a procedure for performing nonlinear static pushover analysis for tsunami loading within the framework of the ASCE 7-16 standard. Through this approach, the user can both estimate the effective systemic lateral load-resisting capacity of a building and the local component demand. This enables the identification of deficiencies in structural elements with respect to the ASCE 7-16 standard acceptance criteria. To demonstrate the procedure, a prototypical reinforced concrete multistory building exposed to high tsunami hazard on the US Northwest Pacific Coast is assessed. This is a building with sufficient height to provide last-resort refuge for people having insufficient time to evacuate outside the inundation zone. The results of the nonlinear static pushover analyses show that the structural system has sufficient lateral strength to resist ASCE 7-16 prescribed tsunami loads, but fails the checks for component-based loading, with the exterior ground-story columns observed to fail in flexure and shear. The example demonstrates that use of the tsunami nonlinear static analysis procedure allows the identification of structural deficiencies such that a targeted strengthening of the building can be conducted (i.e., flexural and shear strengthening of the seaward and inland columns for the case study building presented), leading to significantly reduced costs.
publisherASCE
titleA Procedure for Performing Nonlinear Pushover Analysis for Tsunami Loading to ASCE 7
typeJournal Paper
journal volume148
journal issue2
journal titleJournal of Structural Engineering
identifier doi10.1061/(ASCE)ST.1943-541X.0003256
journal fristpage04021270
journal lastpage04021270-16
page16
treeJournal of Structural Engineering:;2021:;Volume ( 148 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record