Show simple item record

contributor authorYi Shao
contributor authorSarah L. Billington
date accessioned2022-05-07T20:23:12Z
date available2022-05-07T20:23:12Z
date issued2021-10-26
identifier other(ASCE)ST.1943-541X.0003225.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4282358
description abstractUltrahigh-performance concrete (UHPC) typically contains short steel fibers with a fiber volume of 2% or larger. This relatively high fiber volume leads to high UHPC tensile strength, typically larger than 8 MPa, and constitutes 30%–40% of the UHPC material cost. Recent studies show that if the reinforcing ratio is low, the high tensile strength of UHPC results in a low structural drift capacity (e.g., less than 2.5%). To lower the cost and improve the ductility of steel-reinforced UHPC (R/UHPC), this study experimentally and numerically explores the relationship between R/UHPC flexural behavior and UHPC material tensile behavior, which is affected by the fiber volume. Experimental variables include reinforcing ratios (0.96% and 2.10%), fiber volumes (0.5%, 1%, and 2%), and two proprietary UHPC materials. Seven simply supported R/UHPC beams are tested. Experimental results show that (1) reducing the fiber volume has little impact on the maximum crack width at the service limit state and the crushing resistance at the ultimate limit state; and (2) with a low reinforcing ratio, reducing fiber volume increases the structural member ductility and provides more failure warnings at the peak load. To understand the relationship between R/UHPC flexural behavior and more possible variations of material properties, a two-level, five-factor factorial experiment was conducted numerically with different combinations of reinforcing ratios, reinforcing steel properties, and UHPC tensile properties. Numerical results show that higher reinforcing ratios, higher steel postyield hardening strength, and lower UHPC tensile strength lead to a more ductile flexural failure. Finally, a minimum reinforcing ratio is validated to mitigate the possibility of low structural drift capacity (e.g., less than 2.5%).
publisherASCE
titleImpact of UHPC Tensile Behavior on Steel Reinforced UHPC Flexural Behavior
typeJournal Paper
journal volume148
journal issue1
journal titleJournal of Structural Engineering
identifier doi10.1061/(ASCE)ST.1943-541X.0003225
journal fristpage04021244
journal lastpage04021244-17
page17
treeJournal of Structural Engineering:;2021:;Volume ( 148 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record