Show simple item record

contributor authorHiroshi Isoda
contributor authorMasahiro Matsuda
contributor authorSolomon Tesfamariam
contributor authorShinichiro Tamori
date accessioned2022-02-01T21:42:31Z
date available2022-02-01T21:42:31Z
date issued10/1/2021
identifier other%28ASCE%29CF.1943-5509.0001609.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4271882
description abstractThe design procedure considered in the Japanese code for low-rise timber houses (two or fewer stories), is through a wall volume method. The wall volume method entails calculating the shear capacity of each wall through addition of shear walls. However, past earthquake damages highlighted the vulnerability of light timber structures and warrant detailed evaluations to assess the design practice. In this study, load-deformation (P-θ) relations of the wall are combined to estimate the story shear drift. The general calculation of the amount of walls as a design method for a house is very simple. Buildings damaged in recent earthquakes have become of a concern to decision makers, owners, and designers. To validate the wall volume method, 21 full-scale shake table tests are compared with static wall test results. From the analytical and experimental studies, the short-term allowable shear strength in design with the full-scale experiment is about 2.25 times the standard method and about 2.0 times the quality verification method. Regarding the P-θ relationship, the rigidity and maximum load obtained from the experimental tests are 1.2 and 1.3 times larger than the addition, respectively. This paper has highlighted also influences of nonstructural members on the overall response of the structures.
publisherASCE
titleShake Table Test of Full-Size Wooden Houses versus Wall Test Result: Comparison of Load-Deformation Relationship
typeJournal Paper
journal volume35
journal issue5
journal titleJournal of Performance of Constructed Facilities
identifier doi10.1061/(ASCE)CF.1943-5509.0001609
journal fristpage04021043-1
journal lastpage04021043-16
page16
treeJournal of Performance of Constructed Facilities:;2021:;Volume ( 035 ):;issue: 005