Show simple item record

contributor authorZine El Abidine Benzeguir
contributor authorGeorges El-Saikaly
contributor authorOmar Chaallal
date accessioned2022-01-30T21:06:41Z
date available2022-01-30T21:06:41Z
date issued8/1/2020 12:00:00 AM
identifier other%28ASCE%29CC.1943-5614.0001045.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4267672
description abstractFor conventional reinforced concrete (RC) beams, it is well established that the so-called size effect tends to decrease the shear strength attributed to concrete at failure when the size is increased. This contrasts with strengthened RC beams using externally bonded (EB) fiber-reinforced polymer (FRP) sheets or laminates, where very few studies have been devoted to the size effect. The main objective of this study is to examine the size effect of RC T-beams strengthened in shear with EB carbon FRP (CFRP) L-shaped laminates. The experimental investigation involved six RC T-beam laboratory tests performed on geometrically similar beams of two different sizes. Three series of beams were considered, each consisting of medium- and large-sized beams with a total depth of 406 and 605 mm, respectively, as follows: one series of control (unstrengthened) beams with transverse steel stirrups, and two series strengthened in shear using EB-CFEP L-shaped laminates in U-wrap schemes, with and without an anchorage system. The anchorage system considered in this investigation consists of embedding the laminates into the compression zone (flange). The results clearly revealed the effectiveness of specimens with embedded laminates, which achieved a substantially greater shear resistance gain compared to those with no anchorage. Results also confirmed the presence of a size effect in all series. In addition, they revealed an additional size effect related to the CFRP strengthening system in both strengthened series, particularly in anchored specimens despite the higher shear resistance gain they achieved. For instance, the losses in shear strength at failure in large specimens with respect to medium ones were 24% and 16% in strengthened specimens with and without an anchorage system, respectively. Therefore, the anchorage system amplified the decrease in shear strength at failure as the effective depth (d) of the beams increased.
publisherASCE
titleSize Effect of RC T-Beams Strengthened in Shear with Externally Bonded CFRP L-Shaped Laminates
typeJournal Paper
journal volume24
journal issue4
journal titleJournal of Composites for Construction
identifier doi10.1061/(ASCE)CC.1943-5614.0001045
page10
treeJournal of Composites for Construction:;2020:;Volume ( 024 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record