Show simple item record

contributor authorDuoc T. Phan
contributor authorSeyed Mohammad Mojtabaei
contributor authorIman Hajirasouliha
contributor authorT. L. Lau
contributor authorJames B. P. Lim
date accessioned2022-01-30T21:04:52Z
date available2022-01-30T21:04:52Z
date issued8/1/2020 12:00:00 AM
identifier other%28ASCE%29ST.1943-541X.0002715.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4267621
description abstractThe load transfer mechanism in cold-formed steel (CFS) bolted moment connections is mainly through the bolt group in the web of beam elements, which may lead to relatively large bimoment and warping deformations. While the bimoment effects can be considered in the Direct Strength Method (DSM), ignoring the fact that the bolt-group length in the conventional design process can lead to nonconservative solutions. This paper presents an alternative analytical design approach using Eurocode 3 (EC3) effective width method to determine the ultimate flexural strength of CFS bolted moment connections by considering bimoment effects. The results compare very well with previously published experimental test data as well as detailed finite-element models developed in this study. It is shown that a short bolt-group length may lead to up to 25% reduction in the flexural strength of the CFS bolted connections. However, a longer bolt-group length generally results in a moment capacity almost equal to the flexural strength of the CFS channel section. Shape optimization is then conducted using a genetic algorithm (GA) to improve the flexural capacity of the connections by taking into account the bimoment effects. The main design variables are considered to be the relative CFS beam cross-sectional dimensions, while the plate slenderness and dimension limits suggested by EC3 as well as a number of manufacturing and practical end-use constraints are incorporated as design constraints. It is found that, compared with standard cross-sectional dimensions, the optimized sections can improve the flexural strength by as much as 36% for a bolt-group length equal to the depth of beam element.
publisherASCE
titleDesign and Optimization of Cold-Formed Steel Sections in Bolted Moment Connections Considering Bimoment
typeJournal Paper
journal volume146
journal issue8
journal titleJournal of Structural Engineering
identifier doi10.1061/(ASCE)ST.1943-541X.0002715
page13
treeJournal of Structural Engineering:;2020:;Volume ( 146 ):;issue: 008
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record