Show simple item record

contributor authorLisa Choe
contributor authorSelvarajah Ramesh
contributor authorWilliam Grosshandler
contributor authorMatthew Hoehler
contributor authorMina Seif
contributor authorJohn Gross
contributor authorMatthew Bundy
date accessioned2022-01-30T20:11:45Z
date available2022-01-30T20:11:45Z
date issued2020
identifier other%28ASCE%29ST.1943-541X.0002627.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4266667
description abstractThis paper presents the results of compartment fire experiments on four 12.8-m-long composite floor beams with various end support conditions. Specimens were constructed as partially composite beams, consisting of W18×35 steel beams and 83-mm-thick lightweight concrete slabs cast on top of 76-mm-deep ribbed steel deck units. Test variables included two types of simple shear connections (shear-tab and welded-bolted double-angle connections) and the presence or absence of slab continuity over the girders. Each specimen was subjected to gravity loading using hydraulic actuators and 4,000-kW compartment fires produced using natural gas–fueled burners. This study evaluated the characteristics of the fire loading and thermal and structural responses of the specimens. The test results indicated that there were significant effects of thermal restraints on the behavior and failure modes of the specimens with simple shear connections. The specimens resisted gravity loads at large vertical displacements near midspan (approximately a ratio of span length over 20) under fire loading. However, various limit states and vulnerabilities to fires were observed, including local buckling of steel beams near supports, flexural failure (yielding of steel beams and concrete fracture near restrained end supports), and connection failure (weld shear or bolt shear) during heating and cooling, which could lead to partial or total collapse of the floor system.
publisherASCE
titleBehavior and Limit States of Long-Span Composite Floor Beams with Simple Shear Connections Subject to Compartment Fires: Experimental Evaluation
typeJournal Paper
journal volume146
journal issue6
journal titleJournal of Structural Engineering
identifier doi10.1061/(ASCE)ST.1943-541X.0002627
page04020088
treeJournal of Structural Engineering:;2020:;Volume ( 146 ):;issue: 006
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record