Show simple item record

contributor authorAhmed Gouda
contributor authorEhab El-Salakawy
date accessioned2017-12-30T13:04:19Z
date available2017-12-30T13:04:19Z
date issued2016
identifier other%28ASCE%29CC.1943-5614.0000597.pdf
identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4245306
description abstractThis paper presents the test results of five full-scale reinforced concrete (RC) interior slab–column connections. Each specimen consisted of a 2,800-mm square slab with a thickness of 200 and 300-mm square central column stubs. Four slabs were reinforced with glass fiber–reinforced polymer (GFRP) bars and one reference slab was reinforced with steel bars. The connections were subjected to eccentric load with a moment-to-shear ratio equal to 0.15 m. The test parameters included the type and ratio of the reinforcement and concrete compressive strength. Test results revealed that increasing the GFRP reinforcement ratio or the concrete strength increased the connection capacity and decreased the deformation of the tested slabs. Moreover, the GFRP-RC connection that has similar reinforcement rigidity to the steel-RC one showed comparable capacity and deflection at failure. Test results were compared with different available models and design provisions including the Canadian standard, the American guideline, and the Japanese code. The Canadian standard and the Japanese code predicted the punching capacity of the test slabs with better accuracy compared with the American guideline.
publisherAmerican Society of Civil Engineers
titlePunching Shear Strength of GFRP-RC Interior Slab–Column Connections Subjected to Moment Transfer
typeJournal Paper
journal volume20
journal issue1
journal titleJournal of Composites for Construction
identifier doi10.1061/(ASCE)CC.1943-5614.0000597
page04015037
treeJournal of Composites for Construction:;2016:;Volume ( 020 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record