Show simple item record

contributor authorAhmet Can Altunişik
contributor authorFatih Yesevi Okur
contributor authorAli Fuat Genç
contributor authorMurat Günaydin
contributor authorSüleyman Adanur
date accessioned2017-12-30T12:59:28Z
date available2017-12-30T12:59:28Z
date issued2018
identifier other%28ASCE%29CF.1943-5509.0001108.pdf
identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4244243
description abstractFinite-element (FE) model updating is a very effective procedure for determining the uncertainty parameters in a structural model and minimize differences between experimentally and analytically identified dynamic characteristics. This procedure can be practiced with manual and global/local automatic model updating procedures. Automatic model updating is very popular because of its applicability to all kinds of engineering structures to minimize differences, and its damage localization and structural health monitoring. This paper considers a historical masonry bastion to obtain its dynamic characteristics numerically with the finite-element method and experimentally with ambient vibration tests (AVTs). Sensitivity analyses for the uncertainty parameters and manual and automated model updating to minimize differences are also performed. A castle bastion located in Trabzon, Turkey is selected as an application. The FE model of structure is developed in commercial software. The first three natural frequencies are obtained between 5 and 10 Hz, and AVTs are performed under natural excitation using enhanced frequency domain decomposition (EFDD) and subspace structural identification (SSI) techniques. The first three natural frequencies are obtained between 4 and 7 Hz. The comparison of analytically and experimentally identified dynamic characteristics shows a close agreement between mode shapes, but 26% difference in natural frequencies. To minimize the difference, the FE model of the bastion is updated using manual and global/local automated updating, changing its material properties of Young’s modulus and material density. The maximum differences are reduced from 27 to 3% with manual updating, and to 0.02% with automated model updating.
publisherAmerican Society of Civil Engineers
titleAutomated Model Updating of Historical Masonry Structures Based on Ambient Vibration Measurements
typeJournal Paper
journal volume32
journal issue1
journal titleJournal of Performance of Constructed Facilities
identifier doi10.1061/(ASCE)CF.1943-5509.0001108
page04017126
treeJournal of Performance of Constructed Facilities:;2018:;Volume ( 032 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record