description abstractRoofs are one of the construction elements most directly affected by external climate agents and most sensitive to deficiencies caused by errors or lack of maintenance. In this study, 65 construction projects of tile-covered pitched roofs were analyzed, studying the deficiencies found during the execution process, in terms of whether or not the project’s design had been previously controlled. A total of 380 deficiencies were detected, which amounts to an average of 5.85 deficiencies per project studied. Each of these deficiencies was assigned to a location group and assigned a level of importance (as evaluated by peers) to estimate the possible damage it might lead to in the future.
publisherAmerican Society of Civil Engineers
titleMultiparameter Evaluation of Deficiencies in Tiled Pitched Roofs
typeJournal Paper
journal volume31
journal issue2
journal titleJournal of Performance of Constructed Facilities
identifier doi10.1061/(ASCE)CF.1943-5509.0000962
page04016097
treeJournal of Performance of Constructed Facilities:;2017:;Volume ( 031 ):;issue: 002