Show simple item record

contributor authorSchemenauer, Robert S.
contributor authorCurry, Michael J.
date accessioned2017-06-09T17:39:53Z
date available2017-06-09T17:39:53Z
date copyright1979/02/01
date issued1979
identifier issn0021-8952
identifier otherams-9649.pdf
identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4233160
description abstractThe capability of a Mee Industries Model 120 ice particle counter (IPC) to differentiate between ice particles and water drops was investigated in laboratory and field studies. The threshold voltage setting as well as the particle size were found to be critical in determining counting efficiency. The results show that ice crystals are counted with an efficiency more than ten times as high as are water drops of the same average size. Increasing the threshold voltage setting of the instrument increases the discrimination factor but also results in a decrease in the absolute number of particles counted. The availability of concurrent information on particle sizes and concentrations from other probes allows the Mee IPC phase determinations to be made with much greater confidence. Methods for utilizing data from the Mee IPC as well as the limitations of the instrument are discussed.
publisherAmerican Meteorological Society
titleIce Particle/Water Droplet Discrimination with an Optical Ice Particle Counter
typeJournal Paper
journal volume18
journal issue2
journal titleJournal of Applied Meteorology
identifier doi10.1175/1520-0450(1979)018<0215:IPDDWA>2.0.CO;2
journal fristpage215
journal lastpage224
treeJournal of Applied Meteorology:;1979:;volume( 018 ):;issue: 002
contenttypeFulltext