Show simple item record

contributor authorJohnson, Kenneth S.
contributor authorPlant, Joshua N.
contributor authorRiser, Stephen C.
contributor authorGilbert, Denis
date accessioned2017-06-09T17:26:15Z
date available2017-06-09T17:26:15Z
date copyright2015/11/01
date issued2015
identifier issn0739-0572
identifier otherams-85257.pdf
identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4228684
description abstractanderaa optode sensors for dissolved oxygen show remarkable stability when deployed on profiling floats, but these sensors suffer from poor calibration because of an apparent drift during storage (storage drift). It has been suggested that measurement of oxygen in air, during the period when a profiling float is on the surface, can be used to improve sensor calibration and to determine the magnitude of sensor drift while deployed in the ocean. The effect of air calibration on oxygen measurement quality with 47 profiling floats that were equipped with Aanderaa oxygen optode sensors is assessed. Recalibrated oxygen concentration measurements were compared to Winkler oxygen titrations that were made at the float deployment stations and to the World Ocean Atlas 2009 oxygen climatology. Recalibration of the sensor using air oxygen reduces the sensor error, defined as the difference from Winkler oxygen titrations in the mixed layer near the time of deployment, by about tenfold when compared to errors obtained with the factory calibration. The relative error of recalibrated sensors is <1% in surface waters. A total of 29 floats were deployed for time periods in excess of one year in ice-free waters. Linear changes in the percent of atmospheric oxygen reported by the sensor, relative to the oxygen partial pressure expected from the NCEP air pressure, range from ?0.9% to +1.3% yr?1 with a mean of 0.2% ± 0.5% yr?1. Given that storage drift for optode sensors is only negative, it is concluded that there is no evidence for sensor drift after they are deployed and that other processes are responsible for the linear changes.
publisherAmerican Meteorological Society
titleAir Oxygen Calibration of Oxygen Optodes on a Profiling Float Array
typeJournal Paper
journal volume32
journal issue11
journal titleJournal of Atmospheric and Oceanic Technology
identifier doi10.1175/JTECH-D-15-0101.1
journal fristpage2160
journal lastpage2172
treeJournal of Atmospheric and Oceanic Technology:;2015:;volume( 032 ):;issue: 011
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record