Show simple item record

contributor authorNicol, J. C.
contributor authorIllingworth, A. J.
contributor authorDarlington, T.
contributor authorKitchen, M.
date accessioned2017-06-09T17:24:44Z
date available2017-06-09T17:24:44Z
date copyright2013/09/01
date issued2013
identifier issn0739-0572
identifier otherams-84754.pdf
identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4228125
description abstractadar refractivity retrievals can capture near-surface humidity changes, but noisy phase changes of the ground clutter returns limit the accuracy for both klystron- and magnetron-based systems. Observations with a C-band (5.6 cm) magnetron weather radar indicate that the correction for phase changes introduced by local oscillator frequency changes leads to refractivity errors no larger than 0.25 N units: equivalent to a relative humidity change of only 0.25% at 20°C. Requested stable local oscillator (STALO) frequency changes were accurate to 0.002 ppm based on laboratory measurements. More serious are the random phase change errors introduced when targets are not at the range-gate center and there are changes in the transmitter frequency (?fTx) or the refractivity (?N). Observations at C band with a 2-?s pulse show an additional 66° of phase change noise for a ?fTx of 190 kHz (34 ppm); this allows the effect due to ?N to be predicted. Even at S band with klystron transmitters, significant phase change noise should occur when a large ?N develops relative to the reference period [e.g., ~55° when ?N = 60 for the Next Generation Weather Radar (NEXRAD) radars]. At shorter wavelengths (e.g., C and X band) and with magnetron transmitters in particular, refractivity retrievals relative to an earlier reference period are even more difficult, and operational retrievals may be restricted to changes over shorter (e.g., hourly) periods of time. Target location errors can be reduced by using a shorter pulse or identified by a new technique making alternate measurements at two closely spaced frequencies, which could even be achieved with a dual?pulse repetition frequency (PRF) operation of a magnetron transmitter.
publisherAmerican Meteorological Society
titleQuantifying Errors due to Frequency Changes and Target Location Uncertainty for Radar Refractivity Retrievals
typeJournal Paper
journal volume30
journal issue9
journal titleJournal of Atmospheric and Oceanic Technology
identifier doi10.1175/JTECH-D-12-00118.1
journal fristpage2006
journal lastpage2024
treeJournal of Atmospheric and Oceanic Technology:;2013:;volume( 030 ):;issue: 009
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record