Show simple item record

contributor authorMach, Douglas M.
contributor authorRust, W. David
date accessioned2017-06-09T15:34:51Z
date available2017-06-09T15:34:51Z
date copyright1989/06/01
date issued1989
identifier issn0739-0572
identifier otherams-477.pdf
identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4186955
description abstractWe have developed a device to measure lightning-channel propagation velocities. It consists of eight solid state silicon photodetectors mounted behind precision horizontal slits in the focal plane of a 50-mm lens on a 35-mm camera body. Each detector has a 0.1° vertical field of view that is separated from adjacent detector slits by 2.8°. The horizontal field-of-view for each detector is 41° and the total vertical field of view for the device is 21°. The signal from each detector is amplified by a circuit with a 10%?90% rise time of 0.6 ?s and an equivalent decay time of 400 ?s. The eight Photodetector pulses, IRIG-B time, and slow and fast electric field change waveforms are recorded on a 14-track analog tape recorder with an upper frequency response Of 1.0 MHz and a maximum dynamic interchannel timing error of 0.6 ?s. To provide images of lightning geometry and permit time-to-thunder measurements, color video and sound are recorded with a standard VHS video cassette recorder. The return stroke velocity (RSV) device, video camera, and microphone are installed and coaxially aimed in an environmental enclosure on a remotely controlled pan-tilt unit atop our mobile laboratory, permitting the recording of lightning signals at remote sites and while mobile. To evaluate the performance of the RSV device, we have analyzed 12 natural return strokes from Alabama, Florida, and Oklahoma and 4 return strokes triggered at the Kennedy Space Center, Florida. The velocities we determined vary from 1.2 to 2.5?108 m s?1, with an average of 1.7?8 m s?1±0.8 ? 8 m s?1. From comparisons of our results to those of a streaking camera, we find no significant differences between the velocities obtained from the same strokes with the two systems. We also find no differences between the characteristics of the pulses or the velocities calculated from them while the RSV device is moving or stationary.
publisherAmerican Meteorological Society
titleA Photoelectric Technique for Measuring Lightning-Channel Propagation Velocities from a Mobile Laboratory
typeJournal Paper
journal volume6
journal issue3
journal titleJournal of Atmospheric and Oceanic Technology
identifier doi10.1175/1520-0426(1989)006<0439:APTFML>2.0.CO;2
journal fristpage439
journal lastpage445
treeJournal of Atmospheric and Oceanic Technology:;1989:;volume( 006 ):;issue: 003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record