Show simple item record

contributor authorPayne, Richard E.
contributor authorAnderson, Steven P.
date accessioned2017-06-09T14:14:19Z
date available2017-06-09T14:14:19Z
date copyright1999/06/01
date issued1999
identifier issn0739-0572
identifier otherams-1540.pdf
identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4151068
description abstractFor some years, investigators have made measurements of downwelling longwave irradiance with the Eppley Precision Infrared Radiometer (PIR), recording the values of thermopile voltage and body and dome thermistor resistances and combining them in data processing. Part I of this paper reviews previous work on the processing equation and presents an improved equation. It establishes that the standard single-output Eppley has an inherent uncertainty of 5%. By measuring the three possible outputs separately and comparing them in the improved equation, the inherent accuracy can be improved to 1.5%. Part II presents a method of calibrating the Eppley PIR for the three-output equation using an easily constructed blackbody cavity in a temperature bath capable of a 0°?50°C temperature range. Calibration of PIR thermistors is recommended since occasionally one is found out of specifications. An outdoor comparison of 15 PIRs calibrated with the technique was carried out in groups of four, with one PIR used in all of the groups as a standard of comparison. The mean differences and 1-min standard deviations between 12 individual PIRs and this standard over comparison periods of 10?22 days were less than 6.0 and 11 W m?2, respectively. Only two of the PIRs and a standard single-output Eppley PIR (calibrated by Eppley) had mean differences and standard deviations greater than 7 and 11 W m?2, respectively. Although the new calibration procedure yielded consistent results in the mean, at times the longwave measurements diverged by up to 45 W m?2 for several hours. Some of these events are attributable to confirmed pinholes in the dome filter, but others are left unexplained.
publisherAmerican Meteorological Society
titleA New Look at Calibration and Use of Eppley Precision Infrared Radiometers. Part II: Calibration and Use of the Woods Hole Oceanographic Institution Improved Meteorology Precision Infrared Radiometer*
typeJournal Paper
journal volume16
journal issue6
journal titleJournal of Atmospheric and Oceanic Technology
identifier doi10.1175/1520-0426(1999)016<0739:ANLACA>2.0.CO;2
journal fristpage739
journal lastpage751
treeJournal of Atmospheric and Oceanic Technology:;1999:;volume( 016 ):;issue: 006
contenttypeFulltext