Show simple item record

contributor authorKalogiros, J. A.
contributor authorHelmis, C. G.
date accessioned2017-06-09T14:04:33Z
date available2017-06-09T14:04:33Z
date copyright1993/09/01
date issued1993
identifier issn0894-8763
identifier otherams-11958.pdf
identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4147243
description abstractA simple method for correcting the time series of a wet temperature sensor characterized by slow response is presented in this paper. A first-order linear approximation of the heat transfer equation is used for correcting the wet temperature measurements. The sensor cutoff frequency is found by an easy experimental method using the phase spectrum between the wet temperature sensor and a much faster platinum thermometer under low wind speeds (up to 3 m s?1) and relatively dry atmosphere (relative humidity 20%?40%). If such a correction is applied, the wet sensor output along with the computed vapor pressure time series using the psychrometric equation are considerably recovered.
publisherAmerican Meteorological Society
titleFast-Response Humidity Measurements with the Psychrometric Method
typeJournal Paper
journal volume32
journal issue9
journal titleJournal of Applied Meteorology
identifier doi10.1175/1520-0450(1993)032<1499:FRHMWT>2.0.CO;2
journal fristpage1499
journal lastpage1507
treeJournal of Applied Meteorology:;1993:;volume( 032 ):;issue: 009
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record