description abstractA psychrometer was built which features a force-feed wicking system to prevent drying of the wick. A pump recirculates the water over an inner wet-bulb radiation shield. The water cools close to wet-bulb temperature, thereby reducing the radiation error on the wet bulb. The wet-bulb wick is fed by this precooled water which also reduces the conduction error of heat flow in the wick. The design also features quick assembly for easy servicing of the wick.
publisherAmerican Meteorological Society
titleAn Accurate, Low-Maintenance Psychrometer
typeJournal Paper
journal volume20
journal issue12
journal titleJournal of Applied Meteorology
identifier doi10.1175/1520-0450(1981)020<1533:AALMP>2.0.CO;2
journal fristpage1533
journal lastpage1537
treeJournal of Applied Meteorology:;1981:;volume( 020 ):;issue: 012