Show simple item record

contributor authorHongjin Kim
contributor authorHojjat Adeli
date accessioned2017-05-08T20:59:16Z
date available2017-05-08T20:59:16Z
date copyrightDecember 2005
date issued2005
identifier other%28asce%290733-9445%282005%29131%3A12%281794%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/34440
description abstractThe tuned liquid column damper (TLCD) has recently been advanced for vibration control of structures subjected to wind loading. The effectiveness of the semiactive TLCD system and the hybrid viscous fluid damper-TLCD control system recently proposed by the writers is investigated for control of wind-induced motion of high-rise buildings. Simulations are performed on a 76-story building benchmark control problem subjected to wind tunnel test data and stochastic wind loads. It is shown that the semiactive TLCD control system performs comparably to a sample active tuned mass damper (ATMD) system and thus is an attractive alternative to the ATMD system. More significantly, it is shown that the hybrid viscous fluid damper-TLCD system reduces the response of the building substantially more than the semiactive TLCD system at every natural frequency of the building. Furthermore, the hybrid damper-TLCD system is robust in terms of the stiffness modeling error for control of both displacement and acceleration responses. The simulation results show that the proposed hybrid viscous fluid damper-TLCD system can perform effectively under various wind loading conditions.
publisherAmerican Society of Civil Engineers
titleWind-Induced Motion Control of 76-Story Benchmark Building Using the Hybrid Damper-TLCD System
typeJournal Paper
journal volume131
journal issue12
journal titleJournal of Structural Engineering
identifier doi10.1061/(ASCE)0733-9445(2005)131:12(1794)
treeJournal of Structural Engineering:;2005:;Volume ( 131 ):;issue: 012
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record