Show simple item record

contributor authorJ. Gustavo Tumialan
contributor authorNestore Galati
contributor authorAntonio Nanni
date accessioned2017-05-08T20:58:46Z
date available2017-05-08T20:58:46Z
date copyrightAugust 2003
date issued2003
identifier other%28asce%290733-9445%282003%29129%3A8%281047%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/34101
description abstractUnreinforced masonry (URM) walls strengthened with composites were tested to failure at a decommissioned building in St. Louis, Missouri. The walls were subjected to out-of-plane loading. Previous work on URM as well as reinforced masonry walls strengthened with fiber reinforced polymer (FRP) laminates has shown remarkable increases in capacity and ductility. However, most of this research work has been conducted in the laboratory, where, it is difficult to reproduce real field conditions. In this context, this experimental program offered a unique opportunity for performing field experimentation on URM walls strengthened FRP laminates showing that shear compression led to controlling the failure of either the upper or lower boundary masonry units. An analytical model that provides good agreement with the experimental results is also presented. The model computes the applied concentrated out-of-plane load, midheight deflection, and rotations at the supports. The analytical model can be easily modified to take into account distributed loads acting on the wall.
publisherAmerican Society of Civil Engineers
titleField Assessment of Unreinforced Masonry Walls Strengthened with Fiber Reinforced Polymer Laminates
typeJournal Paper
journal volume129
journal issue8
journal titleJournal of Structural Engineering
identifier doi10.1061/(ASCE)0733-9445(2003)129:8(1047)
treeJournal of Structural Engineering:;2003:;Volume ( 129 ):;issue: 008
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record