Show simple item record

contributor authorTony Holden
contributor authorJose Restrepo
contributor authorJohn B. Mander
date accessioned2017-05-08T20:58:36Z
date available2017-05-08T20:58:36Z
date copyrightMarch 2003
date issued2003
identifier other%28asce%290733-9445%282003%29129%3A3%28286%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/34008
description abstractTwo geometrically identical half-scale precast concrete cantilever wall units were constructed and tested under quasi-static reversed cyclic lateral loading. One unit was a code compliant conventionally reinforced specimen, designed to emulate the behavior of a ductile cast-in-place concrete wall. The other unit was part of a precast partially prestressed system that incorporated post-tensioned unbonded carbon fiber tendons and steel fiber reinforced concrete. Hysteretic energy dissipation devices were provided in the latter unit in the form of low yield strength tapered longitudinal reinforcement, acting as a fuse connection between the wall panel and the foundation beam. The conventional precast reinforced wall performed very well in terms of the ductility capacity and energy absorption capability, reaching 2.5% drift before significant strength degradation occurred. The precast partially prestressed wall unit achieved drift levels well in excess of 3% with no visible damage to the wall panel prior to failure. Test results and performance comparisons between the precast partially prestressed wall system and the precast conventionally reinforced unit are presented.
publisherAmerican Society of Civil Engineers
titleSeismic Performance of Precast Reinforced and Prestressed Concrete Walls
typeJournal Paper
journal volume129
journal issue3
journal titleJournal of Structural Engineering
identifier doi10.1061/(ASCE)0733-9445(2003)129:3(286)
treeJournal of Structural Engineering:;2003:;Volume ( 129 ):;issue: 003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record