Show simple item record

contributor authorSwaroop K. Yalla
contributor authorAhsan Kareem
date accessioned2017-05-08T20:57:44Z
date available2017-05-08T20:57:44Z
date copyrightAugust 2000
date issued2000
identifier other%28asce%290733-9445%282000%29126%3A8%28906%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/33446
description abstractTuned liquid column dampers (TLCDs) are a class of tuned liquid dampers that impart indirect damping to the primary structure through oscillations of the liquid column in a U-shaped container. The energy dissipation in the water column results from the passage of the liquid through an orifice with inherent head-loss characteristics. The overall damping in a TLCD depends on the head-loss coefficient and the velocity of the oscillating liquid, and it is nonlinear due to the quadratic damping term. Using the TLCD theory and the equivalent linearization scheme, a new approach has been developed that helps to compute the optimum head-loss coefficient for a given level of wind or seismic excitation in a single step, without resorting to iterations. The optimal damping coefficient and tuning ratio of a TLCD using a single degree of freedom system under the white noise and a set of filtered white noise excitations representing wind and seismic loadings is presented. Optimum values of damping have also been investigated for multiple TLCDs. An example is presented to demonstrate the performance of multiple TLCDs in controlling multiple modes under wind excitation.
publisherAmerican Society of Civil Engineers
titleOptimum Absorber Parameters for Tuned Liquid Column Dampers
typeJournal Paper
journal volume126
journal issue8
journal titleJournal of Structural Engineering
identifier doi10.1061/(ASCE)0733-9445(2000)126:8(906)
treeJournal of Structural Engineering:;2000:;Volume ( 126 ):;issue: 008
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)