description abstractThis paper presents a test program on full-scale reinforced slender shear connected cavity walls subjected to an eccentric compressive loading. A total of nine walls were tested. All specimens were constructed with a partially grouted and reinforced, 190-mm concrete masonry block wythe and a 90-mm burnt clay brick wythe. All had a slenderness ratio of height to backup wythe thickness of 27.8 and, except for one specimen, all walls had a 75-mm wide cavity. The primary variable, was the axial force eccentricity. The eccentricity varied both in magnitude from