description abstractThis paper is to verify the fire resistance of columns made from fire‐resistant (FR) structural steel by means of a full‐scale loaded heat test and numerical analysis. Because of the elements contained, FR steel has higher strength than conventional structural steel at elevated temperatures. Its 0.2% proof stress at 600°C is equal to or greater than two‐thirds the value specified at room temperature. Rock wool, ceramic fire protection, and foaming‐type intumescent coating were used as fire‐protection materials. Using Japanese codes, the high‐temperature strength of steel can be exhibited with building members, the fire‐protection thickness can be reduced below what is required for conventional steel columns, and 1‐h fire resistance can be obtained by intumescent coating with a lower insulation property. Also, deformation and fire‐resistance time can be simulated from the mechanical properties at elevated temperatures and elastoplastic thermal deformation analysis. Furthermore, this study is based on Japanese codes, and results will differ if based on ASTM codes.
publisherAmerican Society of Civil Engineers
titleFire Resistance of Fire‐Resistant Steel Columns
typeJournal Paper
journal volume120
journal issue4
journal titleJournal of Structural Engineering
identifier doi10.1061/(ASCE)0733-9445(1994)120:4(1103)
treeJournal of Structural Engineering:;1994:;Volume ( 120 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record