Show simple item record

contributor authorJ. D. Dolan
contributor authorM. W. White
date accessioned2017-05-08T20:54:30Z
date available2017-05-08T20:54:30Z
date copyrightDecember 1992
date issued1992
identifier other%28asce%290733-9445%281992%29118%3A12%283473%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/31323
description abstractThe results of earthquake tests of light-frame, wood shear walls conducted by several researchers are reviewed. The effect of using adhesives to attach the sheathing material to the framing is considered, specifically, potential problems due to the adhesive strengthening and stiffening of the wall system when subjected to an inertial loading such as an earthquake. None of the current design and building codes used in the United States address the use of adhesives, and engineers may design unsafe structures. Change in probable failure modes from the traditional ductile yielding of the nail connections between the sheathing and the framing to the anchorage connections or adjacent structural components is highlighted. Recommendations for changes that should be made to the building and design codes are suggested. Changes to the seismic design procedures only are recommended and the improved performance of adhesives in shear walls subjected to wind or other applied loads is acknowledged.
publisherAmerican Society of Civil Engineers
titleDesign Considerations for Using Adhesives in Shear Walls
typeJournal Paper
journal volume118
journal issue12
journal titleJournal of Structural Engineering
identifier doi10.1061/(ASCE)0733-9445(1992)118:12(3473)
treeJournal of Structural Engineering:;1992:;Volume ( 118 ):;issue: 012
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record