description abstractA load test of a prestressed concrete, one‐half scale model, flat plate with unbonded tendons is reported. The four panel model was 20 ft (6.1 m) square, 2.75 in. (70 mm) thick, with 8 in. (200 mm) or 7 in. (175 mm) square columns spaced at 10 ft (3 m) centers. A uniform tendon arrangement was used in one slab direction and a banded arrangement was employed in the other direction. Bonded reinforcement was provided in accordance with