description abstractVertical accelerations of circular cylindrical tanks and their contents cause hoop forces in the tank walls. The hoop forces caused by hydrodynamic fluid pressure are additive to those caused by hydrostatic fluid pressure; earthquake‐resistant design of tanks should therefore consider the combined fluid pressure. The design of a prestressed concrete tank wall must be such that under combined hydrostatic and earthquake‐induced hoop forces either: (1) The concrete does not crack (if leaking is not permitted); or (2) the stress in the prestressing wires remains below
publisherAmerican Society of Civil Engineers
titleVertical Accelerations in Prestressed Concrete Tanks
typeJournal Paper
journal volume110
journal issue4
journal titleJournal of Structural Engineering
identifier doi10.1061/(ASCE)0733-9445(1984)110:4(706)
treeJournal of Structural Engineering:;1984:;Volume ( 110 ):;issue: 004