Show simple item record

contributor authorThomas J. Trout
date accessioned2017-05-08T20:46:28Z
date available2017-05-08T20:46:28Z
date copyrightMarch 1983
date issued1983
identifier other%28asce%290733-9437%281983%29109%3A1%2860%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/26706
description abstractFlow measurement devices can cause significant errors in inflowoutflow channel water loss measurements. The device effects, caused by the increased water surface elevation upstream of a device, must be subtracted from measured losses to correctly estimate conveyance water loss. Methods to calculate device effects are given. In channels with small slopes and in which loss rates increase sharply with water surface increases, inflow‐outflow loss measurements should be made in long channel sections with devices which create as little head loss as possible.
publisherAmerican Society of Civil Engineers
titleMeasurement Device Effect on Channel Water Loss
typeJournal Paper
journal volume109
journal issue1
journal titleJournal of Irrigation and Drainage Engineering
identifier doi10.1061/(ASCE)0733-9437(1983)109:1(60)
treeJournal of Irrigation and Drainage Engineering:;1983:;Volume ( 109 ):;issue: 001