Show simple item record

contributor authorKyoungsik Chang
contributor authorGeorge Constantinescu
contributor authorSeung-O. Park
date accessioned2017-05-08T20:45:46Z
date available2017-05-08T20:45:46Z
date copyrightApril 2007
date issued2007
identifier other%28asce%290733-9429%282007%29133%3A4%28361%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/26278
description abstractThe flow past two-dimensional (2D) channel cavities along with the removal of neutrally buoyant or dense miscible contaminants introduced instantaneously inside the cavity are studied using eddy resolving techniques. In the simulations, the incoming boundary layer is laminar and the flow is observed not to transition to turbulence as it is convected over the cavity. As for these flow conditions the main coherent structures in the separated shear layer over the cavity are quasi-dimensional, 2D simulations are performed. It is found that the mechanism of removal of the contaminant is very different between the neutrally buoyant and buoyant cases. In the neutrally buoyant case the contaminant is purged from the cavity mostly due to the interactions between the vortices shed in the separated shear layer with the main recirculation eddies inside the cavity and with the trailing edge corner. In the simulations in which a dense contaminant is introduced inside the cavity, after the initial stages of the mass exchange process, the main phenomenon is the presence of a large amplitude internal wave motion which interacts with a strong cavity vortex situated near the trailing edge corner in between the shear layer and the density interface. The density variation across this oscillatory interface is strong. Through this interaction wisps of denser contaminant are extracted from the region beneath the density interface, before being ejected from the cavity by the separated shear layer vortices. The values of the global mass exchange coefficients for the different phases of the purging process are estimated from simple dead-zone models. As expected, the purging process is delayed in the case in which the density of the contaminant is larger than the one of the carrying fluid.
publisherAmerican Society of Civil Engineers
titlePurging of a Neutrally Buoyant or a Dense Miscible Contaminant from a Rectangular Cavity. I: Case of an Incoming Laminar Boundary Layer
typeJournal Paper
journal volume133
journal issue4
journal titleJournal of Hydraulic Engineering
identifier doi10.1061/(ASCE)0733-9429(2007)133:4(361)
treeJournal of Hydraulic Engineering:;2007:;Volume ( 133 ):;issue: 004
contenttypeFulltext