Show simple item record

contributor authorJames C. Y. Guo
date accessioned2017-05-08T20:45:20Z
date available2017-05-08T20:45:20Z
date copyrightNovember 2006
date issued2006
identifier other%28asce%290733-9429%282006%29132%3A11%281237%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/26030
description abstractThe current design procedure for sizing a single-unit curb opening inlet has been expanded to multiple-unit inlet designs. The decay function derived in this study can consistently convert a single-unit clogging factor to its multiple-unit clogging factor. The design procedure is then revised to apply the clogging factor to the length of on-grade inlets or to the opening area of sump inlets. The revised equation provides a consistent basis for comparison among various inlet sizes on continuous grade or in sump.
publisherAmerican Society of Civil Engineers
titleDesign of Street Curb Opening Inlets Using a Decay-Based Clogging Factor
typeJournal Paper
journal volume132
journal issue11
journal titleJournal of Hydraulic Engineering
identifier doi10.1061/(ASCE)0733-9429(2006)132:11(1237)
treeJournal of Hydraulic Engineering:;2006:;Volume ( 132 ):;issue: 011