| contributor author | James C. Y. Guo | |
| date accessioned | 2017-05-08T20:45:20Z | |
| date available | 2017-05-08T20:45:20Z | |
| date copyright | November 2006 | |
| date issued | 2006 | |
| identifier other | %28asce%290733-9429%282006%29132%3A11%281237%29.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/26030 | |
| description abstract | The current design procedure for sizing a single-unit curb opening inlet has been expanded to multiple-unit inlet designs. The decay function derived in this study can consistently convert a single-unit clogging factor to its multiple-unit clogging factor. The design procedure is then revised to apply the clogging factor to the length of on-grade inlets or to the opening area of sump inlets. The revised equation provides a consistent basis for comparison among various inlet sizes on continuous grade or in sump. | |
| publisher | American Society of Civil Engineers | |
| title | Design of Street Curb Opening Inlets Using a Decay-Based Clogging Factor | |
| type | Journal Paper | |
| journal volume | 132 | |
| journal issue | 11 | |
| journal title | Journal of Hydraulic Engineering | |
| identifier doi | 10.1061/(ASCE)0733-9429(2006)132:11(1237) | |
| tree | Journal of Hydraulic Engineering:;2006:;Volume ( 132 ):;issue: 011 | |
| contenttype | Fulltext | |