Show simple item record

contributor authorNabil F. Ismael
date accessioned2017-05-08T20:35:12Z
date available2017-05-08T20:35:12Z
date copyrightNovember 1989
date issued1989
identifier other%28asce%290733-9410%281989%29115%3A11%281588%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/20382
description abstractThe ultimate oblique pull of bored piles in sand was examined by a field testing program. Tests included axial uplift tests, lateral load tests, and oblique tests at an angle of 30° with the pile axis. The piles used were 101 mm in diameter by 1.5 m long and were installed in predominantly fine, medium‐dense sand. Lateral failure occurred in the oblique tests of the present program; however, both the axial and lateral failure must be considered in practical design. The maximum oblique pull was 74% of the axial pull since the smaller lateral capacity was reached first. Both the lateral and axial capacities were predicted with reasonable accuracy. The critical angle was defined as the angle of inclination of the load from the pile axis at which the failure mode changes from axial to lateral failure. It can be determined if the soil strength parameters and the pile type and geometry are known.
publisherAmerican Society of Civil Engineers
titleField Tests on Bored Piles Subject to Axial and Oblique Pull
typeJournal Paper
journal volume115
journal issue11
journal titleJournal of Geotechnical Engineering
identifier doi10.1061/(ASCE)0733-9410(1989)115:11(1588)
treeJournal of Geotechnical Engineering:;1989:;Volume ( 115 ):;issue: 011
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record