Show simple item record

contributor authorLeslie F. Haider, Jr.
contributor authorWilliam D. Hammond
contributor authorPenny S. Ross
date accessioned2017-05-08T20:33:26Z
date available2017-05-08T20:33:26Z
date copyrightJanuary 1984
date issued1984
identifier other%28asce%290733-9410%281984%29110%3A1%2857%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/19474
description abstractA test program using vibroflotation to density silty sands beneath surface day and silt layers is presented. Vibroflotation compaction columns were constructed along the downstream toe of an embankment dam at two locations. At one location, columns were placed through the dam crest. The sands treated contained between 5% and 35% fines. The test program and construction monitoring are described in detail along with the atypical construction procedure used in the program. Comparisons of before and after standard penetration test and cone penetrometer test results generally indicated no improvement after construction. Failure of the method to density the sand is attributed principally to the presence of significant amounts of fines in the sand.
publisherAmerican Society of Civil Engineers
titleVibroflotation Compaction at Thermalito Afterbay
typeJournal Paper
journal volume110
journal issue1
journal titleJournal of Geotechnical Engineering
identifier doi10.1061/(ASCE)0733-9410(1984)110:1(57)
treeJournal of Geotechnical Engineering:;1984:;Volume ( 110 ):;issue: 001
contenttypeFulltext