Search
Now showing items 1-2 of 2
Measurements of the Tip Clearance Flow for a High-Reynolds-Number Axial-Flow Rotor
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: A high-Reynolds-number pump (HIREP) facility has been used to acquire flow measurements in the rotor blade tip clearance region, with blade chord Reynolds numbers of 3,900,000 and 5,500,000. The ...
An Experimental Investigation of the Flow Through an Axial-Flow Pump
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: The high Reynolds number pump (HIREP) facility at ARL Penn State has been used to perform a low-speed, large-scale experiment of the incompressible flow of water through a two-blade-row ...