Search
Now showing items 1-7 of 7
In Situ Calibration of Moored CTDs Used for Monitoring Abyssal Water
Publisher: American Meteorological Society
Abstract: To monitor changes in heat content and geostrophic volume transport of abyssal water accurately, 50 moored conductivity?temperature?depth (CTD) recorders used for density measurements were calibrated in situ by simultaneous ...
A Method for Data Processing to Obtain High-Quality XCTD Data
Publisher: American Meteorological Society
Abstract: data processing method to obtain high-quality data from an expendable conductivity?temperature?depth (XCTD) profiler is proposed. By adjusting the mismatch of the response time of the temperature and conductivity sensors, ...
Design and Numerical Analysis of Vibration Isolators With Quasi-Zero-Stiffness Characteristics Using Bistable Foldable Structures
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: In this paper, a novel vibration isolator based on a foldable cylinder with a torsional buckling pattern, which is also called Kresling's pattern, is proposed, and the performance of the proposed isolator in terms of ...
In Situ Calibration of Optode-Based Oxygen Sensors
Publisher: American Meteorological Society
Abstract: Eleven optode-based oxygen sensors were used for shipboard hydrographic casts in the North Pacific. Oxygen data from the optode sensors were compared with high-quality oxygen data obtained with discrete water samples, and ...
In Situ Calibration of the SeaBird 9plus CTD Thermometer
Publisher: American Meteorological Society
Abstract: A Sea-Bird Electronics (SBE 35) deep ocean reference thermometer is used with the SBE 9plus CTD system to calibrate the SBE 3 ocean thermometers of the CTD. The SBE 35 is standardized in water-triple-point and gallium-me ...
Deep Ocean Temperature Measurement with an Uncertainty of 0.7 mK
Publisher: American Meteorological Society
Abstract: he uncertainty of deep ocean temperature (~1°C) measurement was evaluated. The time drifts of six deep ocean standards thermometers were examined based on laboratory calibrations as performed by the manufacturer in triple ...
An Expanded Batch-to-Batch Correction for IAPSO Standard Seawater
Publisher: American Meteorological Society
Abstract: We expanded the batch-to-batch offsets of The International Association for the Physical Sciences of the Oceans (IAPSO) Standard Seawater (SSW) batches P145–P163 by intercomparison measurements using salinometers. On the ...