Measurements of Velocity and Wall Shear Stress Inside a PTFE Vascular Graft Model Under Steady Flow Conditions
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: The flow field inside a model of a polytetrafluoroethylene (PTFE) canine artery end-to-side bypass graft was studied under steady flow conditions using laser-Doppler anemometry. The anatomically ...