A Case History of Cracking Failures in Deformed Austenitic Alloy Pipe Operating in the Temperature Range of 1000-1300 Deg F (538-705 Deg C)
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: The results of several cracking failures in fabricated austenitic alloy pipe are reported in detail. These failures were a result of cracking which occurred at the operating temperature in zones ...