YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    Search 
    •   YE&T Library
    • Search
    •   YE&T Library
    • Search
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Search

    Show Advanced FiltersHide Advanced Filters

    Filters

    Use filters to refine the search results.

    Now showing items 1-10 of 11

    • Relevance
    • Title Asc
    • Title Desc
    • Year Asc
    • Year Desc
    • 5
    • 10
    • 20
    • 40
    • 60
    • 80
    • 100
  • Export
    • CSV
    • RIS
    • Sort Options:
    • Relevance
    • Title Asc
    • Title Desc
    • Issue Date Asc
    • Issue Date Desc
    • Results Per Page:
    • 5
    • 10
    • 20
    • 40
    • 60
    • 80
    • 100

    Evaluation by Fluid/Structure-Interaction Spinal-Cord Simulation of the Effects of Subarachnoid-Space Stenosis on an Adjacent Syrinx 

    Source: Journal of Biomechanical Engineering:;2010:;volume( 132 ):;issue: 006:;page 61009
    Author(s): C. D. Bertram
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A finite-element numerical model was constructed of the spinal cord, pia mater, filum terminale, cerebrospinal fluid in the spinal subarachnoid space (SSS), and dura mater. The cord was hollowed ...
    Request PDF

    Possible Sources of Discrepancy Between Sphygmomanometer Cuff Pressure and Blood Pressure Quantified in a Collapsible-Tube Analogue 

    Source: Journal of Biomechanical Engineering:;1992:;volume( 114 ):;issue: 001:;page 68
    Author(s): C. D. Bertram; K. S. A. Butcher
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: This paper examines the assumption that the audible events detected as Korotkov sounds in sphygmomanometry occur when blood pressure equals arm-cuff pressure. Several effects that contribute to ...
    Request PDF

    Erratum: “Possible Sources of Discrepancy Between Sphygmomanometer Cuff Pressure and Blood Pressure Quantified in a Collapsible-Tube Analogue” (Journal of Biomechanical Engineering, 1992, 114, pp. 68–77) 

    Source: Journal of Biomechanical Engineering:;1992:;volume( 114 ):;issue: 002:;page 201
    Author(s): C. D. Bertram; K. S. A. Butcher
    Publisher: The American Society of Mechanical Engineers (ASME)
    Request PDF

    A General Method of Determining the Frequency-Dependent Propagation Coefficient and Characteristic Impedance of an Artery in the Presence of Reflections 

    Source: Journal of Biomechanical Engineering:;1992:;volume( 114 ):;issue: 001:;page 2
    Author(s): C. D. Bertram; S. E. Greenwald
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: An iterative method of calculating propagation parameters at harmonics of heart rate for a uniform vascular segment from a combination of four arterial waveform measurements is presented. ...
    Request PDF

    LDA Measurements of Velocities in a Simulated Collapsed Tube 

    Source: Journal of Biomechanical Engineering:;1997:;volume( 119 ):;issue: 003:;page 357
    Author(s): C. D. Bertram; S. A. Godbole
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A perspex (plexiglas) tube was locally deformed into an almost bi-lobar interior cross section, representative of the localized throat at the downstream end of a collapsed tube conveying a flow. ...
    Request PDF

    The Flow Field Downstream of an Oscillating Collapsed Tube 

    Source: Journal of Biomechanical Engineering:;2005:;volume( 127 ):;issue: 001:;page 39
    Author(s): C. D. Bertram; A. H. Nugent
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A two-component laser Doppler anemometer was used to determine the velocity of aqueous flow in the region from 0.25 to 2.5 diameters downstream of a collapsible tube while the tube was executing ...
    Request PDF

    Oscillations in a Collapsed-Tube Analog of the Brachial Artery Under a Sphygmomanometer Cuff 

    Source: Journal of Biomechanical Engineering:;1989:;volume( 111 ):;issue: 003:;page 185
    Author(s): C. D. Bertram; C. J. Raymond; K. S. A. Butcher
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: To determine whether self-excited oscillations in a Starling resistor are relevant to physiological situations, a collapsible tube conveying an aqueous flow was externally pressurized along only ...
    Request PDF

    PIV Measurements of the Flow Field Just Downstream of an Oscillating Collapsible Tube 

    Source: Journal of Biomechanical Engineering:;2008:;volume( 130 ):;issue: 006:;page 61011
    Author(s): C. D. Bertram; N. K. Truong; S. D. Hall
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: We probed the time-varying flow field immediately downstream of a flexible tube conveying an aqueous flow, during flow-induced oscillation of small amplitude, at time-averaged Reynolds numbers ...
    Request PDF

    The Origins of Syringomyelia: Numerical Models of Fluid/Structure Interactions in the Spinal Cord 

    Source: Journal of Biomechanical Engineering:;2005:;volume( 127 ):;issue: 007:;page 1099
    Author(s): C. D. Bertram; A. R. Brodbelt; M. A. Stoodley
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A two-dimensional axi-symmetric numerical model is constructed of the spinal cord, consisting of elastic cord tissue surrounded by aqueous cerebrospinal fluid, in turn surrounded by elastic dura. ...
    Request PDF

    Laser-Doppler Measurements of Velocities Just Downstream of a Collapsible Tube During Flow-Induced Oscillations 

    Source: Journal of Biomechanical Engineering:;2001:;volume( 123 ):;issue: 005:;page 493
    Author(s): C. D. Bertram; G. Diaz de Tuesta; A. H. Nugent
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The flow field less than one diameter downstream of the end of a collapsible tube executing self-excited oscillations was examined using a two-component fiber-optic laser-Doppler anemometer. The ...
    Request PDF
    • 1
    • 2
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     

    Author

    ... View More

    Publisher

    Year

    Type

    Content Type

    Publication Title

    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian