Passive Wireless Detection of Corrosive Salts in Concrete Using Wire-Based Triggers
Publisher: American Society of Civil Engineers
Abstract: This paper presents an iron wire trigger mechanism that will be used for a new generation of low-cost corrosion sensors that are wireless and do not require batteries or any other external power sources. The corrosion of ...
Wireless Crack Detection in Concrete Elements Using Conductive Surface Sensors and Radio Frequency Identification Technology
Publisher: American Society of Civil Engineers
Abstract: This paper describes the results of an experimental study that uses radio frequency identification (RFID) technology to detect cracking in concrete elements. A RFID-based sensor is used to monitor the change in electrical ...