YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    Search 
    •   YE&T Library
    • Search
    •   YE&T Library
    • Search
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Search

    Show Advanced FiltersHide Advanced Filters

    Filters

    Use filters to refine the search results.

    Now showing items 1-4 of 4

    • Relevance
    • Title Asc
    • Title Desc
    • Year Asc
    • Year Desc
    • 5
    • 10
    • 20
    • 40
    • 60
    • 80
    • 100
  • Export
    • CSV
    • RIS
    • Sort Options:
    • Relevance
    • Title Asc
    • Title Desc
    • Issue Date Asc
    • Issue Date Desc
    • Results Per Page:
    • 5
    • 10
    • 20
    • 40
    • 60
    • 80
    • 100

    Variation of Lumbar Spine Stiffness With Load 

    Source: Journal of Biomechanical Engineering:;1987:;volume( 109 ):;issue: 001:;page 35
    Author(s): W. T. Edwards; R. W. Mann; W. C. Hayes; I. Posner; A. A. White
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Mechanical studies of the Functional Spinal Unit (FSU) in-vitro have shown that the slopes of the load-displacement curves increase with load. This nonlinearity implies that the stiffness of the ...
    Request PDF

    Monitoring Fracture Site Properties With External Fixation 

    Source: Journal of Biomechanical Engineering:;1983:;volume( 105 ):;issue: 002:;page 120
    Author(s): G. S. Beaupre; W. C. Hayes; M. H. Jofe; A. A. White
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: An in-vitro system has been devised to monitor the properties of an idealized fracture site immobilized with a Hoffman-Vidal external fixator. A dial gage was used to measure the relative pin ...
    Request PDF

    Optimization Technique for the Calculation of In Vitro Three-Dimensional Vertebral Motion 

    Source: Journal of Biomechanical Engineering:;1995:;volume( 117 ):;issue: 003:;page 366
    Author(s): M. Shea; W. T. Edwards; A. A. White; W. C. Hayes
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A method for the calculation of translations and Eulerian rotations of an orthogonal axis system with respect to a fixed reference is described with application to the measurement of position ...
    Request PDF

    Three-Dimensional Finite Element Analysis of a Simplified Compression Plate Fixation System 

    Source: Journal of Biomechanical Engineering:;1984:;volume( 106 ):;issue: 004:;page 295
    Author(s): E. J. Cheal; S. M. Perren; W. C. Hayes; A. A. White
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A three-dimensional, linear finite element model was generated for an intact plexiglass tube with an attached six-hole stainless steel compression plate. We examined external forces representing ...
    Request PDF
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     

    Author

    Publisher

    Year

    Type

    Content Type

    Publication Title

    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian