description abstractThe existence of “sampling bias” in individual-realization laser velocimeter measurements is experimentally verified and shown to be independent of sample rate. The experiments were performed in a simple two-stream mixing shear flow with the standard for comparison being laser-velocimeter results obtained under continuous-wave conditions. It is also demonstrated that the errors resulting from sampling bias can be removed by a proper interpretation of the sampling statistics. In addition, data obtained in a shock-induced separated flow and in the near-wake of airfoils are presented, both bias-corrected and uncorrected, to illustrate the effects of sampling bias in the extreme.
publisherThe American Society of Mechanical Engineers (ASME)
titleAn Experimental Verification of Laser-Velocimeter Sampling Bias and Its Correction
typeJournal Paper
journal volume106
journal issue1
journal titleJournal of Fluids Engineering
identifier doi10.1115/1.3242405
journal fristpage5
journal lastpage12
identifier eissn1528-901X
keywordsVelocimeters
keywordsSampling (Acoustical engineering)
keywordsLasers
keywordsMeasurement
keywordsFlow (Dynamics)
keywordsShock (Mechanics)
keywordsErrors
keywordsAirfoils
keywordsWaves
keywordsShear flow AND Wakes
treeJournal of Fluids Engineering:;1984:;volume( 106 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record