description abstractAir release caused by column separation in a pipeline was investigated in a test facility where column separation could be generated for any desired length of time. The temperature, pressure, amount of dissolved air, and the other variables affecting the process were carefully controlled. Tests were made for cases where there was no initial free air in the system and for cases where there was some initial free air. The parameters influencing air release were identified and empirical equations developed for predicting the amount of air released during each cycle of column separation.
publisherThe American Society of Mechanical Engineers (ASME)
titleAir Release During Column Separation
typeJournal Paper
journal volume105
journal issue1
journal titleJournal of Fluids Engineering
identifier doi10.1115/1.3240926
journal fristpage113
journal lastpage118
identifier eissn1528-901X
keywordsSeparation (Technology)
keywordsPipelines
keywordsCycles
keywordsEquations
keywordsTest facilities
keywordsPressure AND Temperature