Show simple item record

contributor authorD. Stern
date accessioned2017-05-08T23:14:02Z
date available2017-05-08T23:14:02Z
date copyrightApril, 1982
date issued1982
identifier issn1050-0472
identifier otherJMDEDB-27998#466_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/96226
description abstractAt present the optimization of a vibration isolator is performed in either the time domain or the frequency domain. A new approach, for optimization in the S-plane, is outlined and performed for the viscous damper. Optimization of the viscous damper in the S-plane results in a line that is defined as the spine of the root locus. Transformations are required between the S-plane and either the frequency domain or the time domain, therefore, time and frequency response plots are included for the spine damper. Two examples are used to illustrate the application of the root locus for single mass and multi-mass models.
publisherThe American Society of Mechanical Engineers (ASME)
titleThe Spine of the Root Locus for the Viscous Damper
typeJournal Paper
journal volume104
journal issue2
journal titleJournal of Mechanical Design
identifier doi10.1115/1.3256369
journal fristpage466
journal lastpage475
identifier eissn1528-9001
keywordsDampers
keywordsOptimization
keywordsVibration isolators AND Frequency response
treeJournal of Mechanical Design:;1982:;volume( 104 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record