Show simple item record

contributor authorFranklin T. Dodge
contributor authorEdgar B. Bowles
date accessioned2017-05-08T23:13:42Z
date available2017-05-08T23:13:42Z
date copyrightMarch, 1982
date issued1982
identifier issn0098-2202
identifier otherJFEGA4-26980#67_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/96038
description abstractIt is shown that the gravity-induced draining of liquid from a tank does not cease when the pressure differential at the outlet is zero if the liquid level is still above the outlet. Instead, either air or exterior liquid is ingested, depending on whether or not the tank outlet is submerged. Analytical models are developed to predict both the onset of ingestion and the subsequent discharge rates; experimental results are used to guide these developments. The models are shown to agree well with tests of draining during air ingestion and during water ingestion when the tank liquid is denser than water. When the tank liquid is less dense than water, however, the predictions of water ingestion are only in qualitative agreement with tests. Some possible reasons for this discrepancy are advanced.
publisherThe American Society of Mechanical Engineers (ASME)
titleDraining of Tanks With Submerged Outlets or Without Vacuum-Relief
typeJournal Paper
journal volume104
journal issue1
journal titleJournal of Fluids Engineering
identifier doi10.1115/1.3240858
journal fristpage67
journal lastpage71
identifier eissn1528-901X
keywordsDrainage
keywordsVacuum
keywordsWater
keywordsPressure AND Gravity (Force)
treeJournal of Fluids Engineering:;1982:;volume( 104 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record