Show simple item record

contributor authorG. R. Mather
date accessioned2017-05-08T23:09:50Z
date available2017-05-08T23:09:50Z
date copyrightNovember, 1980
date issued1980
identifier issn0199-6231
identifier otherJSEEDO-28135#294_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/93841
description abstractThe results of ASHRAE 93-77 instantaneous and all day tests for two Sunpak™ evacuated-tube collectors are presented and discussed in terms of a simple dynamic response model and a biaxial incidence angle modifier approximation. The dynamic model predicts, and experimental results confirm, a residence time type of response rather than the exponential response that is assumed to characterize most collectors. The anisotropic geometries of the two collectors require that their optical properties be described by an incidence angle modifier that depends on both solar altitude and azimuth in the tilted aperture plane. The test results support the idea that this dependence can be characterized with sufficient accuracy by a biaxial approximation which requires that incidence angle modifiers be measured in each of two mutually perpendicular symmetry planes of the collectors. The all-day measurements are compared with the results to be expected from the ASHRAE 93-77 instantaneous tests, and excellent agreement is obtained when the dynamic model is used to account for the time variations in insolation and inlet temperature. It is concluded that the two Sunpak™ evacuated-tube models can be characterized adequately within the scope of ASHRAE 93-77, but that measurements over and above those actually required by this standard are necessary for a complete characterization. In addition, it is recommended that these collectors be tested on a tracking mount because of their long response times. Such instantaneous test results, in combination with the dynamic model, can be used to predict daily and long-term performance under most conditions.
publisherThe American Society of Mechanical Engineers (ASME)
titleASHRAE 93-77 Instantaneous and All-Day Tests of the Sunpak™ Evacuated-Tube Collector
typeJournal Paper
journal volume102
journal issue4
journal titleJournal of Solar Energy Engineering
identifier doi10.1115/1.3266194
journal fristpage294
journal lastpage304
identifier eissn1528-8986
keywordsTemperature
keywordsMeasurement
keywordsSolar energy
keywordsApproximation
keywordsDynamic response AND Dynamic models
treeJournal of Solar Energy Engineering:;1980:;volume( 102 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record