Show simple item record

contributor authorR. B. Jerard
contributor authorS. C. Jacobsen
date accessioned2017-05-08T23:08:12Z
date available2017-05-08T23:08:12Z
date copyrightAugust, 1980
date issued1980
identifier issn0148-0731
identifier otherJBENDY-25658#199_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/93017
description abstractThis paper reports on the application of a “postulate-based” control method for multi-axis artificial arm control. This method uses shoulder muscle EMG’s as control sites, but, unlike previous techniques, the theory is the first that can be rigorously defined in terms of musculoskeletal anatomy, EMG muscle-force relationships, EMG transmission characteristics, muscle recruitment, limb dynamics and normal motion constraints. The control theory results in a deterministic, mathematically expressible set of controller equations, which use the vector of natural limb torques estimated by shoulder EMG signals and a “constraint” for input. The output of the controller equations is a vector of prosthetic torques to be applied to the artificial limb. We report on the implementation of the theory up to the point of laboratory feasibility trials of actual simultaneous above-elbow amputee control of elbow flexion and humeral rotation. Implementation of the theory required: 1) deviation of the controller equations from Newton’s dynamic equations of motion into controller form in conformity with the postulate theory; 2) development of a methodology for estimating natural musculoskeletal torques from EMG signals; 3) hardware and software for experimental testing with actual closed loop amputee control of the prosthesis; and 4) a methodology for evaluating the performance of the prosthesis relative to both alternative prosthetic systems and the natural arm. These tasks were completed and simultaneous multiple-axis control of a prosthetic arm was accomplished by both amputee and nonamputee subjects. Key questions of control compatibility, naturalness, stability, and performance evaluation relative to other prostheses and the natural arm were addressed. Various problems are discussed with the conclusion that this method, despite some difficulties, holds great promise as a practical rehabilitation tool.
publisherThe American Society of Mechanical Engineers (ASME)
titleLaboratory Evaluation of a Unified Theory for Simultaneous Multiple Axis Artificial Arm Control
typeJournal Paper
journal volume102
journal issue3
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.3149574
journal fristpage199
journal lastpage207
identifier eissn1528-8951
keywordsDynamics (Mechanics)
keywordsForce
keywordsRotation
keywordsStability
keywordsControl theory
keywordsControl equipment
keywordsMotion
keywordsHardware
keywordsUnified field theories
keywordsEquations of motion
keywordsProstheses
keywordsTesting
keywordsArtificial limbs
keywordsComputer software
keywordsElectromyography
keywordsEquations
keywordsMuscle
keywordsPerformance evaluation
keywordsSignals AND Musculoskeletal system
treeJournal of Biomechanical Engineering:;1980:;volume( 102 ):;issue: 003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record