Show simple item record

contributor authorL. Thompson
contributor authorO. E. Buxton
date accessioned2017-05-08T23:07:31Z
date available2017-05-08T23:07:31Z
date copyrightMay, 1979
date issued1979
identifier issn0094-9930
identifier otherJPVTAS-28173#113_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/92581
description abstractThe maximum isentropic flow of dry saturated steam using iterative computer techniques with standard (ASME) steam property data is determined. Comparison of this maximum flow with the Napier flow (the calibrating ideal flow for ASME pressure relief valve capacity ratings) reveals significant divergence between the two. A correction factor is developed to be applied to existing ASME safety and safety relief valve capacity ratings to rectify the difference. Experimental flow measurement work verifying the divergence between the maximum isentropic flow and the Napier flow is described.
publisherThe American Society of Mechanical Engineers (ASME)
titleMaximum Isentropic Flow of Dry Saturated Steam Through Pressure Relief Valves
typeJournal Paper
journal volume101
journal issue2
journal titleJournal of Pressure Vessel Technology
identifier doi10.1115/1.3454609
journal fristpage113
journal lastpage117
identifier eissn1528-8978
keywordsFlow (Dynamics)
keywordsSteam
keywordsRelief valves
keywordsSafety
keywordsComputers AND Flow measurement
treeJournal of Pressure Vessel Technology:;1979:;volume( 101 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record