Show simple item record

contributor authorE. K. Levy
contributor authorC. L. Tsai
contributor authorM. P. Groover
date accessioned2017-05-08T23:01:36Z
date available2017-05-08T23:01:36Z
date copyrightFebruary, 1976
date issued1976
identifier issn1087-1357
identifier otherJMSEFK-27635#251_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/89148
description abstractAn analytical study of the effect of crater wear on the response of a remote thermocouple sensor is described. The remote thermocouple sensor is at present being developed as a device for the on-line measurement of tool wear. This technique depends for its operation on the strong influence of wear on the transient temperature variations in the tool. The two-dimensional transient temperature variations in the chip and tool regions are determined using a numerical finite-difference technique. Results are obtained under idealized cutting conditions with a zero wear rate, a normal wear rate, and an accelerated wear rate. Comparisons are made between the three cases to develop relationships for the effect of wear on the temperature at the remote thermocouple location.
publisherThe American Society of Mechanical Engineers (ASME)
titleAnalytical Investigation of the Effect of Tool Wear on the Temperature Variations in a Metal Cutting Tool
typeJournal Paper
journal volume98
journal issue1
journal titleJournal of Manufacturing Science and Engineering
identifier doi10.1115/1.3438828
journal fristpage251
journal lastpage257
identifier eissn1528-8935
keywordsWear
keywordsTemperature
keywordsMetal cutting
keywordsThermocouples
keywordsSensors AND Cutting
treeJournal of Manufacturing Science and Engineering:;1976:;volume( 098 ):;issue: 001