Show simple item record

contributor authorM. G. El-Gendy
contributor authorEhab El-Salakawy
date accessioned2017-05-08T22:32:29Z
date available2017-05-08T22:32:29Z
date copyrightAugust 2016
date issued2016
identifier other48960606.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/82287
description abstractThis paper presents test results of six full-scale glass fiber-reinforced polymer (GFRP) reinforced concrete slab–column edge connections. The test connections included two series with three connections each. The connections of Series 1 investigated the effect of a new type of GFRP shear reinforcement on the punching shear behavior of slab-column edge connections, while those of Series 2 investigated the effect of moment-to-shear ratio. For Series 1, one connection did not have shear reinforcement, while the other two connections had ribbed-deformed GFRP shear studs with headed ends at different radial spacing (120 and 80 mm). For Series 2, three different moment-to-shear ratios were applied to the connections (0.2, 0.4, and 0.6 m). The typical dimensions of the slabs were
publisherAmerican Society of Civil Engineers
titleEffect of Shear Studs and High Moments on Punching Behavior of GFRP-RC Slab–Column Edge Connections
typeJournal Paper
journal volume20
journal issue4
journal titleJournal of Composites for Construction
identifier doi10.1061/(ASCE)CC.1943-5614.0000668
treeJournal of Composites for Construction:;2016:;Volume ( 020 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record