| contributor author | M. G. El-Gendy | |
| contributor author | Ehab El-Salakawy | |
| date accessioned | 2017-05-08T22:32:29Z | |
| date available | 2017-05-08T22:32:29Z | |
| date copyright | August 2016 | |
| date issued | 2016 | |
| identifier other | 48960606.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/82287 | |
| description abstract | This paper presents test results of six full-scale glass fiber-reinforced polymer (GFRP) reinforced concrete slab–column edge connections. The test connections included two series with three connections each. The connections of Series 1 investigated the effect of a new type of GFRP shear reinforcement on the punching shear behavior of slab-column edge connections, while those of Series 2 investigated the effect of moment-to-shear ratio. For Series 1, one connection did not have shear reinforcement, while the other two connections had ribbed-deformed GFRP shear studs with headed ends at different radial spacing (120 and 80 mm). For Series 2, three different moment-to-shear ratios were applied to the connections (0.2, 0.4, and 0.6 m). The typical dimensions of the slabs were | |
| publisher | American Society of Civil Engineers | |
| title | Effect of Shear Studs and High Moments on Punching Behavior of GFRP-RC Slab–Column Edge Connections | |
| type | Journal Paper | |
| journal volume | 20 | |
| journal issue | 4 | |
| journal title | Journal of Composites for Construction | |
| identifier doi | 10.1061/(ASCE)CC.1943-5614.0000668 | |
| tree | Journal of Composites for Construction:;2016:;Volume ( 020 ):;issue: 004 | |
| contenttype | Fulltext | |