Show simple item record

contributor authorT. Y. Yang
contributor authorRakesh K. Kapania
date accessioned2017-05-08T22:05:51Z
date available2017-05-08T22:05:51Z
date copyrightOctober 1983
date issued1983
identifier other%28asce%290733-9399%281983%29109%3A5%281270%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/71241
description abstractIntending to achieve optimum finite element modeling of column supported cooling towers for seismic response studies according to the distributions of dominating bending and membrane stresses and intending to model the vulnerable shell‐column region using discrete column elements and quadrilateral shell elements, a set of elements is adopted, modified or extended. The set includes: (1) A 16 d.o.f. column element; (2) a 48 d.o.f. doubly curved quadrilateral general shell element; (3) a 42 d.o.f. doubly curved general‐membrane transition element; (4) a 21 d.o.f. and 39 d.o.f. doubly curved triangular membrane filler elements; and (5) a 28 d.o.f. doubly curved quadrilateral membrane element. Examples are given to evaluate a single type, combined types, and the whole set of elements with results in good agreement with alternative solutions. These elements may be used for accurate and efficient free vibration analysis of column supported cooling towers. The modeling may be used in seismic response analysis of cooling towers for obtaining detail stress distribution in the vulnerable shell‐column region. This model may be extended to include material nonlinearity in the shell‐column region for the seismic response studies.
publisherAmerican Society of Civil Engineers
titleShell Elements for Cooling Tower Analysis
typeJournal Paper
journal volume109
journal issue5
journal titleJournal of Engineering Mechanics
identifier doi10.1061/(ASCE)0733-9399(1983)109:5(1270)
treeJournal of Engineering Mechanics:;1983:;Volume ( 109 ):;issue: 005
contenttypeFulltext